 FABIA 282 ANAESTHESIA APPARATUS MAJOR

 

SPECIFICATION

1.    Two Gases Rota Meter Oxygen & Nitrous Oxide.

2.    Oxygen Flowmeter Range 100cc/min. to 10 litres/min.,

       Nitrous Oxide Flowmeter range 200cc/min. to 10 litres/min.

3.    Goldman type Halothane Vaporizer.

4.    Built-in parking space for two additional Vaporizers.

5.    Circle Absorber with transparent Cannister

6.    Non-return Cum Pressure Relief Valve to

       minimize risk of back flow of gases

7.    Blows off Valve when pressure exceeds

       200cm of water column fitted.

8.    Emergency Push Button at Front Panel

       Connected to incoming O2 supply (Oxygen Push

       Button ensures free flow of Oxygen at

       35-45 Ltr. at 3.8 bar).

9.    Table Top made of Stainless Steel.

10   Top Tray provided at eye lavel for keeping

       Monitoring Equipments.

11.  Two Self Sealing quick Coupling type gas

       outlet One each for O2, N2O at the rear side for

       Central pipe line connection.

12.  Separate Oxygen Flowmeter for independent

       Oxygen supply.

13.  Sline Stand locate at above right side of Trolley.

14.  Provision to fit Ventilator.

15.  Extended Platform at rear to accommodate

       Two ‘B’ Type Cylinders.

16.  Fitted with four large diameter colour coded Gauges 

       two each for O2 & N2O

17.  Two colour coded extra gauges to show Pipeline Pressure

       O2 & N2O each

18.  Pin Index Yokes Two each for O2 & N2O

19.  Change Over system for Open to Close Circuit.

20.  Redesigned for higher efficiency and reliability Preset

       Regulators two each for O2 and N2O

21.  Four spacious Swivel type Drawers

22.  Writing surface is mounted beneath table top.

23.  Maggill's or Bains Circuit .

24.  Four Castor Trolley with front two lockable Wheels. 

SEFETY FEATURES

·          N2O Automatic cutoff in case failure of Oxygen supply.

·          Low Pressure Oxygen Audible Alarm.

·          ORC (Oxygen Ratio Control) Oxygen concentration

remains above 25%

·          During the process, when Oxygen supply pressure is

deficient, N2O flow gradually decreases till cut-off.

OTHER OPTIONS AND VARIATIONS

*    Alternative Machine configuration: 2-Gas O2/N2O

     low flow O2/N2O/Air 5 tube.

*   Rotameter Backlight Screen with inbuilt re-chargeable

    Battery Backup.

*   Venturi Suction with 600ml Jar for emergency purpose.

*   Low Pressure Oxygen Visual Alarm.

*   Mounting Bracket for Ventilator.

*   Multipara Monitor.

*   Anaesthetic Ventilator.

*   Vaporizers for any agents (customer's preference)

*   Pulse Oximeter.

*   Bulk conversion unit O2/N2O.

 

 
 
 
 
 
 
Click for Quotation
 

ME-202 ANAESTHESIA APPARATUS MAJOR

Features

1.    Long rotating bobbin flowmeter (230 mm) tube calibrated.

2.    Oxygen flowmeter range 100cc/min. to 8 liters/min., Nitrous Oxide flowmeter range 200 cc/min. to 12 liters/min.

3.    Fresh gas outlet cum emergency oxygen unit located at a convenient position.

4.     Plenum type ether vaporizer.

5.    Goldman type halothene vaporizer.

6.     Built-in space for one more vaporizer.

7.     Non return cum pressure relief valve.

8.     Provision to fit ventilator.

9.     Provision to fit carbon dioxide absorber.

10.  Provision to accommodate two Nos. 10 ltr. Cylinders at the back side.

11.  Table top made of stainless steel.

12.  Top tray at eye level to keep monitoring instrument.

13.  Maggill's circuit or bains circuit.

14.  Fitted with two large diameter gauges each for Oxygen and Nitrous Oxide.

15.  Two gauges to show pipeline pressure one for O2 for N2O.

16.  One spacious drawer on smooth runner.

17.  Pin index Yokes two for Oxygen and two for Nitrous Oxide.

18.  Change over system for open and close circuit.

19.  Preset regulators for O2 and N2O two each.

20.  Shelf for Ampule.

SAFETY FEATURES

* N2O CUT OFF IN CASE FAILURE OF OXYGEN SUPPLY.

* LOW PRESSURE OXYGEN AUDIBLE MECHANICAL ALARM.

* HYPOXICGAURD (ROTAMETER ENSURE PROTECTION

AGAINST SINGULAR   FLOW OF N2O UNTIL A MINIMUM

FLOW OF 1.5 LITRE OXYGEN IS RELEASED.)

 

NOTE: Cylinders,Circle Absorber, & other items than the above mentioned specifications are supplied at extra cost

 
 
 
 
 
 
Click for Quotation
 

ME-16 ANAESTHESIA APPARATUS MAJOR

 

SPECIFICATION

1.   Two Gases Rotameter Oxygen & Nitrous-Oxide

2.   Oxygen Flowmeter range 100 cc/min. to

      10 litres/min., Nitrous Oxide Flowmeter

      range 200cc /min. to 12 litres/min.

3.   Standard Fresh Gas Outlet.

4.   Change Over System Open Circuit to Close Circuit.

5.   Emergency Flush Valve at front Panel connected

      to incoming O2 supply

6.   Goldman type Halothane Vaporizer.

7.   Parking space for two additional Vaporizers.

8.   Non-return cum Pressure Relief Valve minimize risk

      of back flow of gases.

9.   Blows off valve when pressure exceeds 200cm of

      water column fitted.

10. Provision to fit Ventilator.

11. Provision to fit Carbon Dioxide Absorber.

12. Extended platform at rear for two 'B' type cylinder.

13. Table top made of Stainless Steel.

14. Top Tray provided at eye lavel for keeping

      Monitoring Equipments.

15. Maggill's or Bains circuit.

16. Three spacious Drawer on smooth runner.

17. Four Castor Trolley with front two lockable Wheels.

18. Pin Index Yokes two for Oxygen and two for

      Nitrous Oxide.

19. High-efficiency Regulators for reliability two each for O2 & N2O.

SAFETY FEATURES

* N2O cut off in case failure of Oxygen supply.

* Low Pressure Oxygen Audible Alarm.

 

NOTE: Cylinders,Circle Absorber, & other items than the above mentioned specifications are supplied at extra cost.

 

 
 
 
 
 
 
Click for Quotation
 

ME-15 ANAESTHESIA APPARATUS MAJOR

 

SPECIFICATION

1.   Two Gases Rotameter Oxygen & Nitrous-Oxide

2.   Oxygen Flowmeter range 100 cc/min. to

      10 litres/min., Nitrous Oxide Flowmeter

      range 200cc /min. to 12 litres/min.

3.   Standard Fresh Gas Outlet.

4.   Change Over System Open Circuit to Close Circuit.

5.   Emergency Flush Valve at front Panel connected

      to incoming O2 supply

6.   Goldman type Halothane Vaporizer.

7.   Parking space for two additional Vaporizers.

8.   Non-return cum Pressure Relief Valve minimize risk

      of back flow of gases.

9.   Blows off valve when pressure exceeds 200cm of

      water column fitted.

10. Provision to fit Ventilator.

11. Provision to fit Carbon Dioxide Absorber.

12. Extended platform at rear for two 'B' type cylinder.

13. Table top made of Stainless Steel.

14. Top Tray provided at eye lavel for keeping

      Monitoring Equipments.

15. Maggill's or Bains circuit.

16. One spacious Drawer on smooth runner.

17. Four Castor Trolley with front two lockable Wheels.

18. Pin Index Yokes two for Oxygen and two for

      Nitrous Oxide.

19. High-efficiency Regulators for reliability two each for O2 & N2O.

SAFETY FEATURES

* N2O cut off in case failure of Oxygen supply.

* Low Pressure Oxygen Audible Alarm.

 

NOTE: Cylinders,Circle Absorber, & other items than the above mentioned specifications are supplied at extra cost.

 
 
 
 
 
 
Click for Quotation
 

 ME-14 ANAESTHESIA APPARATUS MAJOR

SPECIFICATION

 

1. Long rotating bobbin flowmeter (230 mm).

2. Plenum type ether Vaporizer.

3. Goldman type Halothene Vaporizer.

4. Non-return cum pressure relief valve.

5. 50 mm die Oxygen Guages.

6. 50 mm die Nitorious-oxide Guages.

7. Table top stainless steel.

8. Top tray for Monitoring Instruments.

9. Pin Indexed Yokes for Oxygen.

10. Pin Indexed Yokes for Nitorous-oxide.

11. Emergency Oxygen supply button.

12. Outlet.

13. Detachable capacious drawer.

14. Maggill's circuit.

15. Stainless/painted(Powered coated)frame.

16. N2O cut off system.

17. Preset Regulator for O2 & N2O.

18. Wheels with brake.

SAFETY FEATURES 

* N2O cut off in case oxygen pressure falls below 10-15 Pnds..

ANESI-14 is available in Stainless Steel Frame,

ANSEI-14 SS & Painted (Powered Coated) Frame, ANESI-14P

 

 
 
 
 
 
 
Click for Quotation
 

ME-7 PORTABLE ANAESTHESIA APPARATUS

SAFETY FEATURES 

1.       The apparatus fitted with Audible  Alarm.

2.       Rotameter ensures protection against singular flow of Nitrous Oxide until a minimum flow of 1 liter Oxygen is released.

3.       To eliminate the risk of wrong connection, the kit nozels are non Interchangable.

SPECIFICATION

1.       Long rotating bobin flowmeter (230 mm).

2.       Ether Vaporiser or Helothane Vaporiser Goldman type with glass bottle.

3.       Emergency cum outlet.

4.       The above head assemble on angle frame fitted on base box consisting mechanical alarm and nitrous oxide lock.

5.       Bag mount.

6.       Oxygen preset resulator (for bull nose cylinder).

7.       Nitrous oxide preset regulator (for pin index cylinder).

8.       High pressure Nylon ribbed tubing with non interchangeable end fitting.

9.       Spare bodak seal washer & cork washer.

10.   Cylinder ket 2 nos.

11.   Rebreathing Bag (2 liter).

12.   Corrugated tube antistatic.

13.   Expiratory valve.

14.   Angle mount.

15.   Cathetor mount with tube.

16.   Face mask adult.

OPTIONAL Bains Circuit, Goldman, Halothene, Vaporiser, Mask No. 0,1,2,3, Paediatric Circuit, Laryngoscope, Cylinders etc.

 [*ANESI-5 is also available without Safety Features.]